Close

1. Identity statement
Reference TypeConference Paper (Conference Proceedings)
Sitemtc-m16d.sid.inpe.br
Holder Codeisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identifier8JMKD3MGP7W/3DBLHC8
Repositorysid.inpe.br/mtc-m19/2013/01.08.10.49
Last Update2013:02.05.15.38.38 (UTC) administrator
Metadata Repositorysid.inpe.br/mtc-m19/2013/01.08.10.49.36
Metadata Last Update2018:06.05.04.13.42 (UTC) administrator
Secondary KeyINPE--PRE/
Citation KeyGuimarãesSaViPaBeSi:2012:AvMeSi
TitleAvaliação metrológica de um sistema de calibração inndor para piranômetros baseado e um simulador solar / Metrological evaluation of an indoor calibration system for pyranometers using a solar simulator
Year2012
Access Date2024, May 14
Secondary TypePRE CI
Number of Files1
Size496 KiB
2. Context
Author1 Guimarães, Patrícia Lúcia de Oliveira
2 Santana, Márcio Antonio Aparecido
3 Vilela, Waldeir Amaral
4 Paes, Tiago Franca
5 Berni, Luiz Angelo
6 Silva, Luiz Fernando da
Resume Identifier1 8JMKD3MGP5W/3C9JJ2Q
2 8JMKD3MGP5W/3C9JHPG
3 8JMKD3MGP5W/3C9JJBP
4
5 8JMKD3MGP5W/3C9JHMN
Group1 CPT-CPT-INPE-MCTI-GOV-BR
2 CPT-CPT-INPE-MCTI-GOV-BR
3 LAS-CTE-INPE-MCTI-GOV-BR
4
5 LAS-CTE-INPE-MCTI-GOV-BR
Affiliation1 Instituto Nacional de Pesquisas Espaciais (INPE)
2 Instituto Nacional de Pesquisas Espaciais (INPE)
3 Instituto Nacional de Pesquisas Espaciais (INPE)
4
5 Instituto Nacional de Pesquisas Espaciais (INPE)
Author e-Mail Address1 patricia.guimaraes@cptec.inpe.br
2 marcio.santana@cptec.inpe.br
3 waldeir@las.inpe.br
4 tiago@las.inpe.br
5 berni@las.inpe.br
6 fernando.silva@cptec.inpe.br
e-Mail Addressmarcelo.pazos@inpe.br
Conference NameCongresso Brasileiro de Energia Solar, 4; Conferência Latino-Americana da ISES, 5.
Conference LocationSão Paulo – SP
Date18 a 21 de Setembro de 2012
History (UTC)2013-02-05 15:38:38 :: marcelo.pazos@sid.inpe.br -> administrator :: 2012
2018-06-05 04:13:42 :: administrator -> marcelo.pazos@inpe.br :: 2012
3. Content and structure
Is the master or a copy?is the master
Content Stagecompleted
Transferable1
Content TypeExternal Contribution
Keywordsradiação solar
instrumentação ambiental
calibração de radiômetros
solar radiation
environmental instrumentation
indoor calibration
AbstractEste trabalho apresenta a avaliação metrológica de um sistema de calibração indoor de piranômetros que utilizou como fonte de radiação um simulador solar comercial, que é normalmente utilizado para caracterização de células solares de silício. Para validar o método indoor de calibração, foi realizada uma avaliação do simulador solar com relação as suas principais características com o intuito de minimizar as contribuições de incerteza provenientes da fonte de radiação. Ajustouse o simulador solar para alguns níveis de irradiância e o sinal de saída do piranômetro em calibração foi comparado com o sinal obtido na saída de um piranômetro padrão de referência que foi previamente calibrado pelo método outdoor. Foi obtido o Fator de Calibração do piranômetro em teste e sua respectiva incerteza levando-se em consideração as diversas fontes de incerteza do sistema proposto e por fim a incerteza obtida pelo método de calibração indoor foi comparada às incertezas obtidas através do método de calibração outdoor. ABSTRACT: In this work we present the metrological evaluation of an indoor calibration system of pyranometers using as solar radiation source a solar simulator used to characterize silicon solar cells. In order to validate the indoor calibration, the solar simulator was characterized with respect to its main characteristics to minimize the uncertainty contributions from the artificial source of radiation. The solar simulator was adjusted to different irradiance levels and the output signal of the pyranometer under test was compared with the output signal of another pyranometer previously calibrated by the method 'outdoor'. The calibration factor and the uncertainty of the pyranometer under calibration was obtained taking into account the various sources of uncertainty of the proposed system and finally the uncertainty obtained by the method 'indoor' was compared with others obtained by the method 'outdoor'.
AreaFISMAT
Arrangement 1urlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAS > Avaliação metrológica de...
Arrangement 2urlib.net > BDMCI > Fonds > Produção anterior à 2021 > CGCPT > Avaliação metrológica de...
doc Directory Contentaccess
source Directory Contentthere are no files
agreement Directory Content
agreement.html 08/01/2013 08:49 1.0 KiB 
4. Conditions of access and use
data URLhttp://urlib.net/ibi/8JMKD3MGP7W/3DBLHC8
zipped data URLhttp://urlib.net/zip/8JMKD3MGP7W/3DBLHC8
Target FileT253.pdf
User Groupmarcelo.pazos@inpe.br
Visibilityshown
Read Permissionallow from all
Update Permissionnot transferred
5. Allied materials
Mirror Repositoryiconet.com.br/banon/2006/11.26.21.31
Next Higher Units8JMKD3MGPCW/3ESR3H2
8JMKD3MGPCW/3EUPEJL
Citing Item Listsid.inpe.br/mtc-m21/2012/07.13.14.57.40 8
sid.inpe.br/mtc-m21/2012/07.13.14.54.50 5
sid.inpe.br/mtc-m21/2012/07.13.14.54.02 2
Host Collectionsid.inpe.br/mtc-m19@80/2009/08.21.17.02
6. Notes
Empty Fieldsarchivingpolicy archivist booktitle callnumber copyholder copyright creatorhistory descriptionlevel dissemination doi edition editor format isbn issn label language lineage mark nextedition notes numberofvolumes orcid organization pages parameterlist parentrepositories previousedition previouslowerunit progress project publisher publisheraddress readergroup rightsholder schedulinginformation secondarydate secondarymark serieseditor session shorttitle sponsor subject tertiarymark tertiarytype type url versiontype volume
7. Description control
e-Mail (login)marcelo.pazos@inpe.br
update 


Close